3rd Generation Specific Talk about 3rd gen RX-7's here.

Two Stock Fd Pumps?

Thread Tools
 
Search this Thread
 
Old 03-01-2004 | 04:47 PM
  #1  
DeaconFrost's Avatar
Thread Starter
Senior Member
 
Joined: Oct 2003
Posts: 175
From: Chattanooga
Default

will two stock fuel pumps be enough fuel for 550 primaries and 1300 cc secondaries? I want to run about 14-15 psi.



Thanks,

Sean
Old 03-01-2004 | 06:38 PM
  #2  
toddp31's Avatar
Senior Member
 
Joined: Dec 2002
Posts: 826
From: Misawa Japan
Default

I believe that you will be fine, I think Jspec or IGY was running to stock FD pumps with no problems.
Old 03-01-2004 | 07:06 PM
  #3  
FikseRxSeven's Avatar
Senior Member
 
Joined: Jan 2003
Posts: 8,079
From: union, new jersey
Default

hmmm i've never heard of it before, but sounds like a great idea.... from what i hear a supra pump that flows 290L/hr can run the 550/1300 setup, so the 2 fd pumps would pump more
Old 03-02-2004 | 04:58 AM
  #4  
DeaconFrost's Avatar
Thread Starter
Senior Member
 
Joined: Oct 2003
Posts: 175
From: Chattanooga
Default

ok, thanks guys. I thought it should work, but just wanted to make sure.



How should they be wired and connected together? I have been looking for a diagram of some sort for twin pumps, but havent had any luck.



Sean
Old 03-02-2004 | 05:23 AM
  #5  
jspecracer7's Avatar
Senior Member
 
Joined: May 2002
Posts: 4,928
From: Okinawa, Japan
Default

It was me who used the FD pumps. Depending on the fuel pressure your going to run is dependent upon how these pumps will hold up. If your going to run 45 psi static, you'll be fine...just don't run anymore than that or you will have flow problems top end.





What turbo will you be using?



The pumps should be wired up in parallel.
Old 03-02-2004 | 07:20 AM
  #6  
rfreeman27's Avatar
Senior Member
 
Joined: Dec 2002
Posts: 4,107
From: fredneck MD
Default

TheCamel Is going to draw a wiring diagram for twin pumps tonight. It Will be the heavy duty way though.
Old 03-02-2004 | 12:19 PM
  #7  
DeaconFrost's Avatar
Thread Starter
Senior Member
 
Joined: Oct 2003
Posts: 175
From: Chattanooga
Default

I will be using the stock twins (balanced and blueprinted).



so, to run 45 psi static...I will need an FPR?



Thanks for the replies, and thanks to thecamel for the upcoming diagram.



Sean
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
ColinRX7
Test Forum
2
04-10-2004 06:11 PM
Fuel Guy
Group Buys
1
06-19-2002 07:33 PM
Fuel Guy
RX-7 & RX-8 Parts For Sale & Wanted
1
06-11-2002 07:12 AM
AussieRX
2nd Generation Specific
1
11-06-2001 11:18 PM
fd female
RX-7 & RX-8 Parts For Sale & Wanted
0
07-25-2001 12:21 AM

Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 



All times are GMT -5. The time now is 01:25 AM.