3rd Generation Specific Talk about 3rd gen RX-7's here.

Apexi AVC-R not controlling boost properly?

Thread Tools
 
Search this Thread
 
Old 12-17-2005 | 12:43 PM
  #1  
Welsh Dan's Avatar
Thread Starter
Junior Member
 
Joined: Jul 2003
Posts: 12
Default

Righto, further on from the idling problem which has now been fixed ( a dirty and clogged Idle Control Valve), my AVC-R now doesn't want to control the boost.

Its set up to limit boost to 0.75 bar, with 71% solenoid duty.

However, at about 0.3-0.4 bar, the solenoid is clicking like crazy and as soon as I get to 0.75 bar, it carries on going and stops at the boost limit on the PowerFC (1 bar).

I've checked all connections and they're fine (and correct), and presumably as the solenoid is clicking, then that too must be connected.

Could it be possible that the solenoid is broken? I'm going to test it tomorrow with one borrowed off a friend, but if it is, where would I get a replacement Apexi solenoid from?
Old 12-18-2005 | 08:37 AM
  #2  
Welsh Dan's Avatar
Thread Starter
Junior Member
 
Joined: Jul 2003
Posts: 12
Default

Further to above, someone suggested that the wastegate could be jammed. Presumably as I can hear it chattering its not jammed shut? There are no kinks in the lines. I've not managed to test it yet, but are these the symptoms of a dead solenoid?
Old 12-18-2005 | 08:49 AM
  #3  
sweet7's Avatar
Senior Member
 
Joined: Jun 2003
Posts: 1,430
From: Stacked outside you're trailer door
Default

Sometimes, there can be nothing wrong with anything except for the simple fact that an automatic BC isnt controlling things perfectly. If the problem persists I recommned picking up a Holloman or some other manual BC and see if that solves things.
Old 12-18-2005 | 11:50 AM
  #4  
Welsh Dan's Avatar
Thread Starter
Junior Member
 
Joined: Jul 2003
Posts: 12
Default

I've replaced the solenoid and it's still doing it. If I increase the boost on the AVC-R, it appears to be able to control it and vents it via the wastegate, but its having a real problem with 0.75 bar.



It seems strange that i've got a problem though as its been fine until friday when it suddenly started doing it
Old 12-21-2005 | 08:35 AM
  #5  
sweet7's Avatar
Senior Member
 
Joined: Jun 2003
Posts: 1,430
From: Stacked outside you're trailer door
Default

Did the symptoms come up when it got cold out. I say **** it and pick up an MBC.
Old 12-23-2005 | 06:32 AM
  #6  
jspecracer7's Avatar
Senior Member
 
Joined: May 2002
Posts: 4,928
From: Okinawa, Japan
Default

do you have a full exhaust? If so you'll find a hell of a time limiting boost.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Arnetts7
RX-7 & RX-8 Parts For Sale & Wanted
0
11-06-2006 01:54 AM
SPD Racing FC
RX-7 & RX-8 Parts For Sale & Wanted
4
06-11-2004 07:22 PM
Lost Time
RX-7 & RX-8 Parts For Sale & Wanted
0
12-17-2002 12:46 AM
speedysupplies
RX-7 & RX-8 Parts For Sale & Wanted
0
12-04-2002 09:22 PM
speedysupplies
RX-7 & RX-8 Parts For Sale & Wanted
0
11-29-2002 02:55 PM

Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 



All times are GMT -5. The time now is 07:20 AM.